Emergency controls – Snorkel TL34-01-sn000123+ User Manual

Page 27

Advertising
background image

21

Emergency Procedures (from the Ground) – Without Power

1. Turn the 2 ball valves fitted under the cabinet 90 degrees (

Fig 16)– photo below shows

normal operating position.

2. Now pull on the red emergency lower knob on the solenoid fitted to the top and botton

boom cylinders.

(FIG. 17)

Start with the bottom boom cylinder first to ease access to the top boom

cylinder.

3. The 2 ball valves MUST be returned to the normal operating position (as shown)

before operating the machine. If they are not, you will not be able to elevate the

Emergency Battery Isolating Plug
This plug when disconnected, will isolate the batteries from the power pack and operating

circuits.

(FIG. 18)

NOTE: Before operation of the machine, it is important that both the Operator and some other

responsible person on site, is aware of the position and function of the following:

EMERGENCY CONTROLS

FIG. 16

BALL VALVES

FIG. 17

RED EMERGENCY LOWER KNOB

FIG. 18

EMERGENCY BATTERY

DISCONNECT PLUG