28

Slew Drive Gears.

The slew drive gear is designed to be largely maintenance free. However, we recommend the

gear teeth be greased on a monthly basis with a high pressure grease. Additionally, the ring

gear and gear box should be greased on a six monthly basis. The grease nipple for the ring gear

is on the top face of the slew gear, set between the fixing bolts. It can be accessed by lifting one

of the side covers, and slewing the structure appropriately.

The ring gear should be inspected on a six monthly basis for excessive play. It is unlikely there

will be any wear if the machine is maintained correctly.

To check the gear, place a payload of approximately 80Kg in the platform. Elevate the lower

boom to approximately half way. Then gently elevate the top boom, whilst observing the ring

gear. Excessive wear will be observed by noticing more than 0.5mm movement between the

inner and outer bearing rings.

Checking Limit Switch Operation.

The limit switches require no maintenance, other than a visual inspection, on a pre operation

basis. This is an important check, to ensure the switch is not mechanically damaged, and

the roller is always in contact with the cam, when not under load.

The switch operation can be simply checked, by observing the LED display when deploying the

stabilizers. As an outrigger foot touches the ground and becomes loaded, the appropriate light

will change to green. This indicates that the switch contact has operated correctly

If the LED displays green at any other time then the machine must not be operated, until the

fault is rectified.

MAINTENANCE

Grease

Nipple

Grease

Nipples

Outriggers

under load

Outriggers NOT

under load