9 MAINTENANCE

LEVEL SENSOR

W A R N I N G

!

!

Never perform service while the platform is elevated without first blocking the elevating assembly. DO NOT

stand in the elevating assembly area while deploying or storing the brace.

The Level Sensor Is located on the chassis between the scissor sections and is covered with a protective

metal box.

The Level Sensor is located on the chassis of

the machine
These units are sealed and pre-set and require

no recalibration or adjustment.

HYDRAULIC FLUID

The hydraulic fluid reservoir is located in the control module door.
NOTE: Never add fluid if the platform is elevated.

CHECK HYDRAULIC FLUID

Make sure that the platform is fully

1.

lowered.
Open the chassis door.

2.

Remove the filler cap from the hydraulic

3.

fluid reservoir.
Check the fluid level on the dipstick on the

4.

filler cap.
Add the appropriate fluid to bring the level

5.

to the FULL mark. See «Specifications» on

page 21.

Figure 10: Level Sensor

Figure 12: Hydraulic Fluid Reservoir and Dipstick

Advertising