5. Automatic Shut-offs and Circuit Breakers

RCD/ELCB Outlet (option)

Figure 5.1 - RED/ELCB Outlet

The RCD (Re sid ual Cur rent De vice) is lo cated at
the base and will pro tect against short cir cuits to
earth. When there is a short cir cuit the RCD will
shut down the 230v AC power to the plat form out -
let.

To re set the out let dis con nect the power tool lead
from the plat form box and re set the RCD at the
base.

If the prob lem per sists call a trained ser vice tech ni -
cian.

Main Circuit Breaker

Figure 5.2 - Main Circuit Breaker

There is only one cir cuit breaker, on a stan dard
MHP13/35, that is ac ces si ble to the op er a tor. Its
pur pose is to pro tect the elec tri cal cir cuits from
elec tri cal over loads. When the cir cuit breaker trips
(pops out) push it back in then at tempt to use the
MHP13/35. If the cir

cuit breaker trips a sec ond

time, take the MHP13/35 out of ser vice and re fer
the prob lem to a qual i fied trained ser vice tech ni -
cian for re pair.

Outriggers

Figure 5.3 - Outriggers

The MHP13/35 booms can not be raised un less the
out rig gers are set and the lift en able light on the
lower con trol box is lit. Once the booms are raised
from the stowed po si tion the out rig gers be come dis -
abled un til the booms are stowed in the travel po si -
tion.