Troubleshooting

Section

5.0

SPECIAL TOOLS

Remove hose from pump port and connect

pressure gauge.

Hydraulic settings must be checked whenever a

component is repaired or replaced.

Remove counterbalance valves and “bench test”

them if they are suspect.

Connect a pressure guage of appropriate range to

the test port located on the hydraulic manifold.

Correct pressure settings are listed in the hydraulic

schematic.

The following is a list of tools which may be required

to perform certain maintenance procedures on the

AB38.

• Flow Meter with Pressure Gauge

(

Snorkel P/N: 067040-000).

• 0-69 bar (0-1000 psi) Hydraulic Pressure Gauge with

Adapter Fittings (

Snorkel P/N: 014124-010).

• 0-207 bar (0-3000 psi) Hydraulic Pressure Guage

with Adapter Fittings (

Snorkel P/N: 014124-030).

• Adapter Fitting (

Snorkel P/N: 063965-002).

• Inclinometer (

Snorkel P/N: 010119-000)

• Crimping Tool (

Snorkel P/N: 028800-009)

• Terminal Removal Tool (

Snorkel P/N: 028800-006)

• Calibrator EZcal (

Snorkel P/N: 504560-001)

ADJUSTMENT PROCEDURES

CHECKING PUMP PRESSURES

DIAGNOSTICS USING EZCAL

DISPLAY

The EZcal Display can be switched into calibration

mode to become an invaluable tool when

troubleshooting on this machine.

Switch the machine on, press and hold Esc for

5 seconds until “SNORKEL EBOOM” is displayed

than select diagnostics, the following menu’s are

available:

1.

SYSTEM -

Display status of joystick trigger or enable switches.

ENABLED

B+ SUPPLY

TRACTION

PUMP

TILT

HEIGHT
LOAD
OVERLOADED
ELEVATED

2. FUNCTIONS-

DRIVE

STEER

LL (LOWER LIFT)

UL (UPPER LIFT)

JIB (N/A)
BASKET
TELE
SLEW
INTERLOCK

3. DIGITALS

4.

5.

VERIOUS

VERIOUS
VERIOUS

ANALOG
OUTPUT

Displays the condition of all digital inputs to the relevant controller & matrix, refer

to the following table and the circuit diagram on page 6.1 for full list of I/O’s.

Demand ON or OFF, Armature & Field Current and SEM600 controller

Temperature.

Displays Battery Voltage

Pump Motor Voltage and Current and P600 Controller Tempreture
Displays tilt angle of the machine in X and Y, bothshould be less than 3 degrees
N/A
Displays load as a percentage of SWL
Yes or No
Yes or No

These display the percentage demand for each function.

Displays the condition of all analogue inputs to relevant controller & matrix.
Displays the condition of all outputs from the relevant controller & matrix.