SERVICE (cont.)

If voltage is present as described, reconnect the black
wire to the limit thermostat from the terminal block,
the limit thermostat is operating properly.
If voltage is not present as described, refer to the

Wiring Diagrams

and check brewer wiring harness.

Removal and Replacement:
1. Remove all wires from the limit thermostat termi-

nals.

2. Carefully remove the two #8-32 nuts securing the

limit thermostat to tank lid and remove limit ther-
mostat.

3. Carefully secure new limit thermostat to tank lid.
4. Refer to Fig. 19 when reconnecting the wires.