SECTION 2 - PREPARATION AND INSPECTION

3120883

– JLG Lift –

2-9

Optional On Board Generator

EXHAUST GAS HAZARD. RUN THE GENERATOR IN A WELL VEN-
TILATED AREA ONLY.

WHEN THE GENERATOR ENABLE CONTROL LOCATED IN THE
PLATFORM CONTROL BOX IS IN THE ON POSITION AND THE
GROUND EMERGENCY STOP SWITCH IN ON (PULLED OUT), THE
GENERATOR WILL START AUTOMATICALLY WHEN THE BAT-
TERIES REACH A LOW-CHARGE STATE AUTOMATICALLY
CHARGING THE BATTERIES.

NOTE: The engine will automatically shut down under the

following conditions:

High Engine Oil Temperature
Low Engine Oil Pressure
Engine Overspeed
Generator Overvoltage

TO AVOID INJURY FROM AN EXPLOSION, DO NOT SMOKE OR
ALLOW SPARKS OR A FLAME NEAR BATTERY DURING SERVIC-
ING. ALWAYS WEAR EYE AND HAND PROTECTION WHEN SER-
VICING BATTERIES.

Battery Charging (On Board Charger)

1.

For maximum battery life:

a. Avoid completely discharging the batteries.

b. Fully charge the batteries each day the machine

is used.

c. Charge the batteries at available times between

full charges.

d. Be sure the battery fluid covers the battery

plates before charging, but to avoid overflow, do
not top off the fluid level until charging.

2.

To charge the batteries, connect the charger to a
115 or 220 volt source with a 20 amp minimum
capacity.

3.

The charge cycle is complete when the ammeter
reads 0 amps. Any reading indicates the charge
cycle is not complete.

4.

The Charger will shut off automatically when the bat-
teries are fully charged.

5.

Depleted batteries will take approximately 17 hours
to charge.

Updated 11-3-99