JLG 3969electric Service Manual User Manual

Page 39

Advertising
background image

SECTION 3 - TROUBLESHOOTING

3120881

– JLGSizzor –

3-9

Table 3-6. Control Module Settings for Machines After and Including Serial Number 020071522

SETTING

3369E

3969E

Software*

104

104

Max Current

400

400

Acc. Delay

1.5

1.5

Dec. Delay

0.5

0.5

Off Level Creep

0

0

Max Speed

85

85

Cut Back 1 Elev.

13

10

Cut Back 2 Slope

60

60

Pump Acc.

3

3

Pump Threshold

20

20

Table 3-7. Control Module Settings for Machines Before Serial Number 020071522

SETTING

3369E

3969E

Software*

102

102

Max Current

400

400

Acc. Delay

1.5

1.5

Dec. Delay

0.5

0.5

Off Level Creep

0

0

Max Speed

85

85

Cut Back 1 Elev.

13

10

Cut Back 2 Slope

60

60

Pump Acc.

3

3

Pump Threshold

20

20

*Password: 73461829

*Password: 73461829

Advertising