JLG 3969electric Service Manual User Manual
Page 39
Advertising
SECTION 3 - TROUBLESHOOTING
3120881
– JLGSizzor –
3-9
Table 3-6. Control Module Settings for Machines After and Including Serial Number 020071522
SETTING
3369E
3969E
Software*
104
104
Max Current
400
400
Acc. Delay
1.5
1.5
Dec. Delay
0.5
0.5
Off Level Creep
0
0
Max Speed
85
85
Cut Back 1 Elev.
13
10
Cut Back 2 Slope
60
60
Pump Acc.
3
3
Pump Threshold
20
20
Table 3-7. Control Module Settings for Machines Before Serial Number 020071522
SETTING
3369E
3969E
Software*
102
102
Max Current
400
400
Acc. Delay
1.5
1.5
Dec. Delay
0.5
0.5
Off Level Creep
0
0
Max Speed
85
85
Cut Back 1 Elev.
13
10
Cut Back 2 Slope
60
60
Pump Acc.
3
3
Pump Threshold
20
20
*Password: 73461829