PRE-START & FUNCTION CHECKS

To be performed at beginning of each work shift or at each change of

operator.

The safety, efficiency and service life of your handler will be increased by

performing the operational checks listed below.

Before entering the platform, be sure to complete all necessary warm-

up and operational checks outlined in the Operators Manual supplied

with the TF6-42.

Also, complete the following pre-start inspection and function checks
before use or each time the operator changes.

PRE-START INSPECTION

1. Cleanliness - Check all surfaces for leakage (oil, fuel, or battery fluid) or

foreign objects. Report any leakage to the proper maintenance personnel.

2. Decals & Placards - Check all decals and placards for cleanliness and

legibility. Make sure none of the decals and placards are missing. Make
sure all illegible decals and placards are cleaned or replaced.

3. Operators and Safety Manuals - Make sure a copy of the Transformer

Series Work Platform Operator Manual, the EMI Aerial Platform Safety
Manual, and ANSI Manual of Responsibilities is enclosed in the manual
storage box.

4. “Walk-Around” Inspection - See pages P6.2 and P6.3 for the walk-

around inspection procedure. Report any differences to the proper

maintenance personnel.

5. Fuel - Ensure that fuel reservoir level is adequate. Add proper fuel as

necessary.

6. Hydraulic Oil - Check the hydraulic oil level. Report low levels to the

proper maintenance personnel. Add hydraulic oil as required.

7. Function Check - Once the “Walk-Around” Inspection is complete, perform

a functional check of all systems in an area free of overhead and ground

level obstructions.

FUNCTION CHECK

1. From the cab with no load in platform:

a. Operate all functions and observe for proper operation.

b. Check for proper operation of auxiliary power (manual descent) shown

on page 3.2 in the TF6-42 Operator Manual.

c. Ensure that all machine functions are disabled when the Emergency

Stop Button is activated.

d. Perform axle locking test shown on pages P7.0 & P7.1.

2. From the platform control console:

a. Operate all functions and observe for proper operation.

b. Check all variable speed control switches for proper operation.

c. Check for proper operation of auxiliary power (manual descent).

d. Perform axle locking test shown on pages P7.0 & P7.1.

Check all tires and rims periodically
for damage due to impact. Replace

before use if damage is detected.

WARNING

!

If any function or system does not

operate properly, cease operation

immediately! Report the problem
to proper maintenance personnel.

Do not operate machine until it is

in a safe and proper operating