4.3

MACHINE OPERATION

The following sequence of basic procedures must be fol-
lowed to safely operate the machine.

1.

At the ground control station, set power PLAT/OFF/
GRND key switch to the PLAT position to operate
from platform controller, or GRND to operate from
ground controls.

NOTE: Check that the Emergency Stop button on ground

and platform controller are in the reset position for
operation. Also check that Emergency/Manual
Decent Control valve is closed (lower access hole in
rear cover).
If LED’S are flashing a fault code on the platform
controller box at machine power-up, see Section-3,
“Troubleshooting” of the Service and Maintenance
Manual for information on reading fault codes.

2.

Check LED strip on the platform controller for cur-
rent battery charge level before operating lift to be
certain charge is sufficient to complete your work
task. If the battery charger is plugged into an AC
outlet, drive functions on the machine will be locked
out.

WORK AREA MUST BE A SMOOTH, FIRM AND LEVEL SURFACE
FREE OF HOLES, LARGE CRACKS OR DEBRIS ON SURFACE.
THE WORK SURFACE MUST BE CAPABLE OF SUPPORTING THE
WEIGHT OF THE MACHINE PLUS THE PLATFORM’S MAXIMUM
RATED LOAD CAPACITY. ALWAYS CHECK THE BUBBLE LEVEL
INDICATOR ON BASE FRAME TO BE SURE MACHINE IS LEVEL
BEFORE RAISING PLATFORM.

3.

Inspect work area before operating lift.

Platform Loading

The platform maximum rated load capacity is displayed
on a decal located on the platform. The maximum rated
load capacity includes the combined weight of the opera-
tor and any materials, tools, etc. placed in the platform
with the operator.

Maximum rated load capacity for all platforms (Except
Extendible)
is as follows:

* Extendible Platform available only for 20VP.

Interlock Switch Operating Conditions

Table 4-3. shown, lists machine response to various inter-
lock switch positions.

Table 4-1. Maximum Rated Load Capacity

(for all platforms except Extendible)

Model

Max. Capacity

(CE - Euro)

10VP

160 kg (350 lb.)

15VP

160 kg (350 lb.)

20VP

160 kg (350 lb.)

Table 4-2. Maximum Rated Load Capacity

(for Extendible Platform*)

Model

Max. Capacity

(CE - Euro)

10VP

Not Available*

15VP

Not Available*

20VP

160/120 kg (350/265 lb.)

Table 4-3.

Machine Interlock Switch Operating Conditions.

Elevation/

Speed Switch

Drive Cutout

(PHP System)

Tilt Status

Brake Status

Controller Response

mast retracted

bars raised

(not tilted)

engaged

Full Drive and Lift

mast retracted

bars raised

(not tilted)

disengaged

Drive and Lift disabled

mast extended

bars lowered

(not tilted)

engaged

Drive 25% maximum

mast extended

bars lowered

(not tilted)

engaged

Drive disabled

mast retracted

bars raised

(tilt)

engaged

Lift disabled

mast retracted

bars raised

(tilt)

disengaged

Drive and Lift disabled

mast retracted

bars raised/battery charger

plugged-in

(not tilted)

engaged