JLG 26MRT Operator Manual User Manual

Page 11

Advertising
background image

SECTION 1 - SAFETY PRECAUTIONS

3120891

– JLG Sizzor –

1-5

Platform-to-structure transfers at elevated positions are
discouraged. Where transfer is necessary, enter/exit
through the gate only with the platform within 0.3m (1 ft) of
a safe and secure structure. 100% tie-off is also required
in this situation utilizing two lanyards. One lanyard must
be attached to the platform with the second lanyard
attached to the structure. The lanyard connected to the
platform must not be disconnected until such time the
transfer to the structure is safe and complete.

Keep oil, mud, and slippery substances cleaned from
footwear and the platform floor.

Electrocution Hazards

This machine is not insulated and does not provide pro-
tection from contact with an electrically charged conduc-
tor.

Maintain safe clearance from electrical lines, apparatus, or
any energized (exposed or insulated) parts in accordance
with the Minimum Safe Approach Distance (MSAD) as
specified in Table 1-1. Allow for machine movement and
electrical line swaying.

Maintain a clearance of at least 3m (10 ft) between any
part of the machine and its occupants, their tools, and
their equipment from any electrical line or apparatus car-
rying up to 50,000 volts. One foot additional clearance is
required for every additional 30,000 volts or less.

DO NOT MANEUVER MACHINE OR PERSONNEL INSIDE PROHIB-
ITED ZONE (MSAD). ASSUME ALL ELECTRICAL PARTS AND
WIRING ARE ENERGIZED UNLESS KNOWN OTHERWISE.

Tipping Hazards

Ensure that the ground conditions are adequate to sup-
port the maximum tire load indicated on the tire load
decals located on the chassis adjacent to each wheel. Do
not travel on unsupported surfaces.

The user should be familiar with the driving surface before
driving. Do not exceed the allowable sideslope and grade
while driving.

Table 1-1.Minimum Safe Approach Distances (M.S.A.D.)

Voltage Range

(Phase to Phase)

MINIMUM SAFE APPROACH

DISTANCE

in Meters (Feet)

0 to 300V

AVOID CONTACT

Over 300V to 50 KV

3 (10)

Over 50KV to 200 KV

5 (15)

Over 200 KV to 350 KV

6(20)

Over 350 KV to 500 KV

8 (25)

Over 500 KV to 750 KV

11 (35)

Over 750 KV to 1000 KV

14 (45)

DANGER: DO NOT maneuver machine or personnel inside PROHIB-
ITED ZONE. ASSUME all electrical parts and wiring are ENERGIZED
unless known otherwise.

Advertising