Bolt usage and torque application, Hydraulic lines and electrical wiring, Hydraulic system – JLG 15SP Service Manual User Manual

Page 20: Lubrication and servicing, Batteries, Mast chain inspection procedure, Chain stretch tolerance -5

Advertising
background image

SECTION 2 - SERVICE PROCEDURES

2-6

– JLG Lift –

3120775

Bolt Usage and Torque Application

Use bolts of proper length. A bolt which is too long will
bottom before the head is tight against its related part. If a
bolt is too short, there will not be enough thread area to
engage and hold the part properly. When replacing bolts,
use only those having the same specifications of the origi-
nal, or one which is equivalent.

Unless specific torque requirements are given within the
text, standard torque values should be used on heat-
treated bolts, studs, and steel nuts, in accordance with
recommended shop practices. (See Section-1, Torque
Charts)

Hydraulic Lines and Electrical Wiring

Clearly mark or tag hydraulic lines and electrical wiring, as
well as their receptacles, when disconnecting or removing
them from the unit. This will assure that they are correctly
reinstalled.

Hydraulic System

Keep the system clean. If evidence of metal or rubber par-
ticles is found in the hydraulic system, drain and flush the
entire system.

Disassemble and reassemble parts on clean work sur-
face. Clean all metal parts with non-flammable cleaning
solvent. Lubricate components, as required, to aid assem-
bly.

Lubrication and Servicing

Components and assemblies requiring lubrication and
servicing are shown on the Lubrication Chart in Section 1.
Service applicable components with the amount, type,
and grade of lubricant recommended in this manual, at
the specified intervals. When recommended lubricants are
not available, consult your local supplier for an equivalent
that meets or exceeds the specifications listed.

Batteries

Clean batteries, using a non-metallic brush and a solution
of baking soda and water. Rinse with clean water. After
cleaning, thoroughly dry batteries and coat terminals with
an anti-corrosion compound.

Mast Chain Inspection Procedure

Inspect mast chains for the following conditions:

Wear: Always inspect that segment of chain that operates
over a sheave. As the chain flexes over the sheaves, joints
and plate edges very gradually wear. Chain “stretch” can
be measured using a manufacturers wear scale or steel
tape. When chains have elongated 3% they must be
removed and replaced. Refer to Table 2-3 for proper chain
specifications and allowable stretch tolerances. Peening
and wear of chain plate edges are caused by sliding over
a chain worn contact face of a sheave, or unusually heavy
loads. All of the above require replacement of the chain
and correction of the cause. Chain side wear, noticeable
when pin heads and outside plates show a definite wear
pattern, is caused by misalignment of the sheave/chain
anchors and must be corrected promptly. Do not repair
chains; if a section of chain is damaged, replace the entire
chain set.

Rust and Corrosion: Rust and corrosion will cause a
major reduction in the load carrying capacity of the chain,
because these are primary reasons for side plate crack-
ing. The initial lubrication at the factory is applied in a hot
dip tank to assure full penetration into the joint. Do not
steam clean or degrease chains. At time of chain installa-
tion, factory lube must be supplemented by a mainte-
nance program to provide a film of oil on the chains at all
times. If chains are corroded, they must be inspected,
especially the outside plates, for cracks in-line with the
pins. If cracks are found, replace the chain; if no cracks
are discovered, lubricate the chains by dipping in heated
oil, and reinstall on the machine. Keep chains lubricated.

Fatigue Cracks: Fatigue is a phenomenon that affects
most metals, and is the most common cause of chain
plate failures. Fatigue cracks are found through the link
holes, perpendicular (90 degrees) from the pin in-line
position. Inspect chains carefully after long time use and
heavy loading for this type of crack. If any cracks are dis-
covered, replace all chains, as seemingly sound plates

Table 2-3. Chain Stretch Tolerance

Chain Size

Pin to Pin

Measurement

Allowable Stretch

.50" pitch

12" or 24 pitches

.24 in./12 in. span

.625 pitch

15" or 24 pitches

.30 in./15 in. span

Advertising
This manual is related to the following products: