8 fault code troubleshooting tables, Fault code troubleshooting tables -11, See table 6-5 – JLG DVSP Series Service Manual User Manual

Page 125: Fault code troubleshooting tables

Advertising
background image

SECTION 6 - TROUBLESHOOTING

3121136

– JLG Lift –

6-11

6.8

FAULT CODE TROUBLESHOOTING TABLES

Machine in Drive Speed Cut-Back (Turtle) Mode All The Time

Overview of Procedure

Under normal machine operation once the platform is elevated the machine’s maximum drive speed is reduced to 1/4 the
normal drive speed of when the platform is fully lowered. This is detected with a drive speed cut-back (proximity) switch
mounted at the base of the mast assembly and a target mounted on the mast assembly. When the mast is elevated and the
target raised the proximity switch then cuts back the machine drive speed. When machine is in the drive speed cut-back
mode a turtle is displayed on the Ground Control Module LCD display.

Check For These Obvious Conditions First:

• Mast drive speed cut-back (proximity) switch and target plate secure and undamaged.

• Both Pot Hole Protection Bar Limit switches secure and undamaged.

Table 6-5. Machine In Drive Speed Cut-Back (Turtle) Mode All The Time

STEP

ACTION

SPEC

YES

NO

1.

The Pot-Hole-Protection system bars should be raised when the
platform is fully lowered. Check if the Pot-Hole-Protection bars are
down when the platform is fully lowered.

Check the

mechanical

operation of

the PHP System

Go to Step 2

2.

With the platform fully lowered, check for continuity on the Cutback
Proximity Switch wires between pins-8 and 18 on the P2 connector
at the Ground Control Module.

Go to Step 3

Repair or Replace

Speed Cutback

(Proximity)

Switch

3.

With the platform fully lowered, bars raised, check for continuity on
the Right Side PHP bar limit switch, between pins-9 and 19 on the P2
connector at the Ground Control Module.

Repair or Replace Right Side

PHP Limit Switch

Go to Step 4

4.

With the platform fully lowered, bars raised, check for continuity on
the Left Side PHP bar limit switch, between pins-10 and 20 on the P2
connector at the Ground Control Module.

Repair or Replace Left Side

PHP Limit Switch

Advertising