Table 4-1. DVL/DVSP Ground Control Module - Field Programmable Settings and Factory Preset.

Level-2: Service Level Settings

On LCD Display:

YES =

!

HIGH =

Level-3: Operator Level Settings

NO =

LOW =

LEVEL

PROGRAMMABLE ITEM

FACTORY

PRESET

SETTING RANGE

2

Back to Main

Return to Programming Menu

3

Set Language

NOTE: There are two production modules available at this

time, one for North/South American and European
Languages, and one for Asian Languages.

1

1 - English

6 - Italian

2 - German

7 - Swedish

3 - Dutch

8 - Brazilian Portuguese

4 - French

9 - Finnish

5 - Spanish

2

1 - English

3 - Japanese

2 - Chinese

2

Set Maximum Lift Up Speed

100%

0 - 100%

2

Set Maximum Lift Down Speed

100%

0 - 100%

2

Zero the On-Board Tilt Sensor

NO

YES/NO

2, 3

Set Sleep Time

5 MINS

0 - 60 MINS

2

Set Polarity Of Left Pot Hole Input 1

2

0 - Disabled / 1 - LOW / 2 - HIGH

2

Set Polarity Of Right Pot Hole Input 2

2

0 - Disabled / 1 - LOW / 2 - HIGH

2

Set Polarity Of Up Limit/elevation Input

HIGH

HIGH/LOW

2

Set Polarity Of Charger Inhibit

HIGH

HIGH/LOW

2, 3

Set Polarity Of The Keypad Code

LOW

HIGH/LOW

2

Set Polarity Of Ancillary Input 1

LOW (a)

HIGH/LOW

2

Set Polarity Of Ancillary Input 2

LOW (b)

HIGH/LOW

2, 3

Enable Detection Of Horn Open Circuit

NO (c)

YES/NO

2, 3

Enable Detection Of Beacon Open Circuit

NO (c)

YES/NO

2

Enable Obstruction Sensor System (OSS)

NO

YES/NO

2

Enable Detection Of Aux. #1 Open Circuit

NO (d)

YES/NO

2

Enable Detection Of Aux #2 Open Circuit

NO (d)

YES/NO

2

Acceleration (Platform Lowered)

40

1 - 100

2

Deceleration (Platform Lowered)

45

1 - 100

2

Turn Acceleration (Platform Lowered)

30

1 - 100

2

Turn Deceleration (Platform Lowered)

30

1 - 100

2

Maximum Forward Speed (Platform Lowered)

100

1 - 100

2

Minimum Forward Speed (Platform Lowered)

30

1 - 100

2

Maximum Reverse Speed (Platform Lowered)

100

1 - 100

2

Minimum Reverse Speed (Platform Lowered)

20

1 - 100

2

Maximum Turn Speed (Platform Lowered)

30

1 - 100

2

Minimum Turn Speed (Platform Lowered)

10

1 - 100

2

Minimum Forward Speed (Platform Elevated)

20

1 - 100

2

Minimum Reverse Speed (Platform Elevated)

20

1 - 100

2

Maximum Turn Speed (Platform Elevated)

5

1 - 100

2

Motor Compensation

90 mOhms

0 - 500 mOhms

3

Forward Alarm Disable

NO

YES/NO

3

OSS Diagnostic

NO

YES/NO

2

Mode Select Delay (Drive/Lift Mode active before timeout)

5 Sec.

0 - 60 Seconds

2

Invert Lift Direction

X

YES/NO

2

Lift Lock Delay

5 Sec.

0 - 60 Seconds

Notes: (a) DVSP Models equipped with stock-picker platform and mid-gate interlock (drive inhibit) switch are factory preset to HIGH.

(b) DVSP Models equipped with 12 ft. lift-limit-switch option are factory preset to HIGH.
(c) DVSP Models this feature is standard equipment and are factory preset to YES.
(d) This circuit is currently unused on both DVL/DVSP Models.