SECTION 6 - TROUBLESHOOTING

3121136

– JLG Lift –

6-13

Code 02 - Left PHP Bar - UP

Check For These Obvious Conditions First:

• Obstruction under LEFT pot hole bar.

• Obstruction around the actuator assembly at the base of the mast.

Code 03 - Right PHP Bar - UP

Check For These Obvious Conditions First:

• Obstruction under RIGHT pot hole bar.

• Obstruction around the actuator assembly at the base of the mast.

Table 6-7. Code 02 - Left PHP Bar - UP

STEP

ACTION

SPEC

YES

NO

CHECK THE FOLLOWING WITH THE PLATFORM ELEVATED 3 TO 4 FEET (1 TO 1.5m)

1.

Go to the 20 pin molex connector at the Ground Control Module,
back probe to check for continuity of pin 10, (BLK #8 wire) with pin
20, (ORG/RED 49-1 wire). Is there continuity?

Replace Ground

Control Module

Go to Step 2

2.

Check the actuator cables for adjustment or damage.

Adjust or Replace

Go to Step 3

3.

Check the PHP limit switch(s) at both sides of the machine for dam-
age, adjustment and for continuity through switch to ground when
bars are down.

Replace, Adjust

or Repair Wiring

Table 6-8. Code 03 - Right PHP Bar - UP

STEP

ACTION

SPEC

YES

NO

CHECK THE FOLLOWING WITH THE PLATFORM ELEVATED 3 TO 4 FEET (1 TO 1.5m)

1.

Go to the 20 pin molex connector at the Ground Control Module,
back probe to check for continuity of pin 9, (BLK #9 wire) with pin
19, (ORG/RED 49-2 wire). Is there continuity?

Replace Ground

Control Module

Go to Step 2

2.

Check the actuator cables for adjustment or damage.

Adjust or Replace

Go to Step 3

3.

Check the PHP limit switch(s) at both sides of the machine for dam-
age, adjustment and for continuity through switch to ground when
bars are down.

Replace, Adjust

or Repair Wiring