Code 11 - left drive motor - short circuit, Code 12 - right drive motor - short circuit, Code 13 - traction module - in fold back – JLG DVSP Series Service Manual User Manual

Page 130: Code 11 - left drive motor - short circuit -16, Code 12 - right drive motor - short circuit -16, Code 13 - traction module - in fold back -16, See table 6-14, See table 6-15, See table 6-16

Advertising
background image

SECTION 6 - TROUBLESHOOTING

6-16

– JLG Lift –

3121136

Code 11 - Left Drive Motor - Short Circuit

Check For These Obvious Conditions First:

• Wiring harness from (M1) connector on Traction Control Module to Left Drive Motor for damage.

Code 12 - Right Drive Motor - Short Circuit

Check For These Obvious Conditions First:

• Wiring harness from (M2) connector on Traction Control Module to Left Drive Motor for damage.

Code 13 - Traction Module - In Fold Back

Check For These Obvious Conditions First:

• Machine is operating on a continuous grade or rough terrain.

Table 6-14. Code 11 - Left Drive Motor - Short Circuit

STEP

ACTION

SPEC

YES

NO

1.

Remove the M1 connector from the Traction Control Module and
check both the pins to the drive motor for any voltage.
(Ground the meter to the Ground Control Module - Negative (–) lug.)

No Voltage

This circuit

should be

isolated. Repair

or Replace

Components as

Required

Go to Step 2

2.

Check for continuity of both the pins to ground.

No Ground

Replace
Traction

Control Module

Table 6-15. Code 12 - Right Drive Motor - Short Circuit

STEP

ACTION

SPEC

YES

NO

1.

Remove the M2 connector from the Traction Control Module and
check both the pins to the drive motor for any voltage.
(Ground the meter to the Ground Control Module - Negative (–) lug.)

No Voltage

This circuit

should be

isolated. Repair

or Replace

Components as

Required

Go to Step 2

2.

Check for continuity of both the pins to the drive motor to ground.

No Ground

Replace
Traction

Control Module

Table 6-16. Code 13 - Traction Module - In Fold Back

STEP

ACTION

SPEC

YES

NO

1.

Allow machine to cool the traction module for 30 minutes. Does the
machine operate OK after cooling.

Replace Traction

Module

NOTE: If this is a recurring problem compare current draw of your machine with Traction Control Module specifications in

Table 6-3 - Amperage Draw for Various Components.

Advertising