Code 16 - lift down valve - short circuit, Code 17 - ground control module - in fold back, Code 18 - alarm - short circuit – JLG DVSP Series Service Manual User Manual

Page 132: Code 16 - lift down valve - short circuit -18, Code 17 - ground control module - in fold back -18, Code 18 - alarm - short circuit -18, See table 6-19, See table 6-20, See table 6-21

Advertising
background image

SECTION 6 - TROUBLESHOOTING

6-18

– JLG Lift –

3121136

Code 16 - Lift Down Valve - Short Circuit

Check For These Obvious Conditions First:

• Damaged wiring in the lift down valve wiring harness or a damaged lift down valve coil.

Code 17 - Ground Control Module - In Fold Back

Check For These Obvious Conditions First:

• Has machine been operating on a continuous grade or rough terrain for a long period of time.

Code 18 - Alarm - Short Circuit

Check For These Obvious Conditions First:

• Damaged wiring in the alarm wiring harness or a damaged alarm.

Table 6-19. Code 16 - Lift Down Valve - Short Circuit

STEP

ACTION

SPEC

YES

NO

1.

At the Ground Control Module, P1 connector, check the voltage
across pins 10 and 3 to the lift down valve coil. Is reading within
specification?

0 - 2V DC

Go to Step 2

Replace Ground

Control Module

2.

Remove the wire terminals at the lift down valve coil. Check resis-
tance reading of the coil. Is coil within specification?

24.5 Ohms

Go to Step 3

Replace Coil

3.

With the terminals still removed from the lift down valve coil, check
continuity of the wires from pins 10 and 3 on the P1 connector to the
lift down valve.

.00 Ohms

Repair or Replace

Wiring

Table 6-20. Code 17 - Ground Control Module - In Fold Back

STEP

ACTION

SPEC

YES

NO

1.

Allow Ground Control Module to cool for 30 minutes. Does the
machine operate OK after cooling.

Replace Ground

Control Module

NOTE: If this is a recurring problem compare current draw of your machine with Ground Control Module specifications in

Table 6-3 - Amperage Draw for Various Components.

Table 6-21. Code 18 - Alarm - Short Circuit

STEP

ACTION

SPEC

YES

NO

1.

At the Ground Control Module, P1 connector, check the voltage
across pins-13 and 6 to the alarm. Is reading within specification?

0 - 2V DC

Go to Step 2

Replace Ground

Control Module

2.

Remove the wire terminals at the alarm, check continuity of each of
the wires from pins 13 and 6 on the P1 connector to the alarm end.

Replace the

Alarm

Repair or

Replace Wiring

Advertising
This manual is related to the following products: