SECTION 6 - TROUBLESHOOTING

3121136

– JLG Lift –

6-21

Code 23 - Horn - Disconnected

Check For These Obvious Conditions First:

• Is machine equipped with a horn unit.

Code 24 - Auxiliary #1 Circuit - Short Circuit

Check For These Obvious Conditions First:

• Damaged wiring in the Auxiliary #1 Component wiring harness or a damaged Component.

Table 6-26. Code 23 - Horn - Disconnected

STEP

ACTION

SPEC

YES

NO

1.

Is machine equipped with a horn unit.

Go to Step 3

Got to Step 2

2.

At the Ground Control Module enter the programming mode, check
if the horn open circuit detection is enabled.

Disable It

Replace Ground

Control Module

3.

Check voltage at the P1 connector on the Ground Control Module
between pin-14 and pin-7. Is reading within specification?

2 - 4 V DC

Replace Ground

Control Module

Go to Step 4

4.

Remove the wire terminals at the horn, check continuity of each of
the wires from pins-14 and 7 on the P1 connector to the horn end.

Replace the

Horn

Repair or

Replace Wiring

Table 6-27. Code 24 - Auxiliary #1 Circuit - Short Circuit

STEP

ACTION

SPEC

YES

NO

1.

At the Ground Control Module, P1 connector, check the voltage
across pins-9 and 2 to the horn. Is reading within specification?

0 - 2V DC

Go to Step 2

Replace Ground

Control Module

2.

Remove the wire terminals at the horn, check continuity of each of
the wires from pins-9 and 2 on the P1 connector to the component
end.

Replace the
Component

Repair or

Replace Wiring