Code 27 - Auxiliary #2 - Disconnected

Check For These Obvious Conditions First:

• Is machine equipped with a component on the Auxiliary #2 circuit.

Code 28 - Reserved

Code 29 - Reserved

Table 6-30. Code 27 - Auxiliary #2 - Disconnected

STEP

ACTION

SPEC

YES

NO

1.

Is machine equipped with a

component on the Auxiliary #2 circuit

.

Go to Step 3

Got to Step 2

2.

At the Ground Control Module enter the programming mode, check
if the Auxiliary #2 open circuit detection is enabled.

Default = NO

Disable It

Replace Ground

Control Module

3.

Check voltage at the P1 connector on the Ground Control Module
between pin-8 and pin-1. Is reading within specification?

2 - 4 V DC

Replace Ground

Control Module

Go to Step 4

4.

Remove the wire terminals at the Aux. #2 component, check conti-
nuity of each of the wires from pins-8 and 1 on the P1 connector to
the Aux. #2 component.

Replace the
Component

Repair or

Replace Wiring