SECTION 6 - TROUBLESHOOTING

6-28

– JLG Lift –

3121136

Codes 41 thru 46 - OSS - Sensor 1 through 6 - Fault Condition

Check For These Obvious Conditions First:

• Is there an obstruction under the sensor showing the fault?

• Is the faulted sensor mounted properly and securely to the platform base frame?

12.

At the Ground Control Module (P-4 connector) check voltage
between pin-8 and pin-2, place positive (+) lead on pin-8.

24V (DC)

Repair or

Replace, Junc-

tion Box to

Ground Control

Module

Wire Harness

Replace Ground

Control Module

Table 6-36. Codes 41 thru 46 - OSS - Sensor 1 through 6 - Fault Condition

STEP

ACTION

SPEC

YES

NO

1.

Is machine equipped with an OSS system?

Got to Step 4

Go to Step 2

2.

At the Ground Control Module, enter programming mode and view if
OSS is enabled. Is OSS enabled?

X = No

Go to Step 3

Replace Ground

Control Module

3.

In Service Level Programming mode, Disable Obstruction Senor
System.

X=No

Go to Step 4

4.

Replace the sensor showing the fault. Does this correct the prob-
lem.

Done

Go to Step 5

5.

Replace the complete OSS system, module and sensors.

Table 6-35. Code 40 - OSS - No Communication with Ground Control Module (Continued)

STEP

ACTION

SPEC

YES

NO