SECTION 6 - TROUBLESHOOTING

3121136

– JLG Lift –

6-29

Codes (100 - 199) Ground Control Module - Fault Condition

Check For These Obvious Conditions First:

• That all battery and harness connectors secure and undamaged on Ground Control Module.

• Batteries have sufficient charge.

• Confirm that the static ground strap attached under base frame is secure and undamaged.

Table 6-37. Codes (100 - 199) Ground Control Module - Fault Condition

STEP

ACTION

SPEC

YES

NO

1.

Recycle machine power 5 times allowing a 10 second interval
between each power recycle. Does fault clear?

Done

Go to Step 2

2.

Which code number is displaying?

Code 103

Go to Step 3

Replace

Ground Control

Module

Code 119

Go to Step 5

3.

Confirm that both installed batteries are 12 Volt DC.

12V DC

Go to Step 4

Replace with

proper Batteries

4.

Check battery voltage while charger is operating. Is voltage within
specification?

Maximum of

31 Volts DC

Replace

Ground Control

Module

Repair or Replace

Battery Charger

5.

Remove the communications cable, P5 connector at the Ground
Control Module and round connector at the Traction Control Module.
Check continuity of all three (3) wires in the communications cable
from end to end. P5 - Pins 2, 3, and 4.

Go to Step 6

Repair or Replace

Wire(s)

6.

With communications cable still disconnected at both ends, check
for continuity between Pins 2, 3, and 4 at the P5 connector end.

Repair or Replace

Wires

Go to Step 7

7.

Plug the communications cable on the Traction Control Module to
the round socket on the opposite end of the module. Does this fix
problem?

Done

Replace

Ground Control

Module