Codes (200 - 299) Platform Control Console - Fault Condition

Check For These Obvious Conditions First:

• Damage to Platform Control Console wiring harness.

• Secure harness connections from Platform Control Console to Platform Junction Box to Ground Control Module.

• Confirm that the static ground strap attached under base frame is secure and undamaged.

Table 6-38. Code (200 - 299) Platform Control Console - Fault Condition

STEP

ACTION

SPEC

YES

NO

1.

Recycle machine power 5 times allowing a 10 second interval
between each power recycle. Does fault clear?

Done

Go to Step 2

2.

Which 200 code number is displaying?

Code - 200/207/213

Go to Step 3

Replace

Platform

Control Module

Code - 202/205/206

Go to Step 4

3.

Remove the 9 pin Platform Control Module connector from the
side of the Platform Junction Box and the P4 connector at the
Ground Control Module. Check continuity from the P4 connector,
pin-5 to Junction Box pin-3 and P4, pin-9 to Junction Box pin-4.
Is there continuity on these wires?

Replace

Platform

Control Module

Repair or

Replace Wiring

4.

Perform the Joystick Calibration Procedure in Section 4.5 of this
Service Manual. Does this clear the fault code?

Done

Replace

Platform

Control Module