SECTION 4 - CONTROL COMPONENTS

3121136

– JLG Lift –

4-7

4.4

GROUND CONTROL MODULE -
SERVICE PROCEDURE

IMPORTANT

DO NOT ATTEMPT TO DISASSEMBLE THE GROUND CONTROL MOD-
ULE IF MACHINE IS STILL UNDER WARRANTY. OPENING THE
GROUND CONTROL MODULE WHILE THE MACHINE IS UNDER WAR-
RANTY WILL VOID THE WARRANTY. IF UNDER WARRANTY
REQUEST A REPLACEMENT MODULE FROM THE FACTORY.

The DVL Series and DVSP Ground Control Module allows
for field replacement of two (2) components internal to the
module.

• Emergency Stop Switch

• Power Selector Switch (Key)

IMPORTANT

ELECTROSTATIC DISCHARGE CAN DAMAGE COMPONENTS ON THE
INTEGRATED CIRCUIT BOARD. PLACE THE GROUND CONTROL
MODULE ON A NON-CONDUCTIVE SURFACE WHEN OPENING.

1. Cover/LCD Assembly

4. Emergency Stop Switch

7. Heat Sink Base/Main Board Assembly

2. Power Selector Switch Nut

5. Power Selector Switch

8. Cover Attach Screws

3. Emergency Stop Button

6. Main Board to LCD Ribbon Cable Connector

Figure 4-3. Ground Control Module Components.

1

4

5

8

7

2

6