SECTION 4 - CONTROL COMPONENTS

4-8

– JLG Lift –

3121136

Cover Removal/Installation

IMPORTANT

THE MAIN CIRCUIT BOARD AND THE SMALLER LCD CIRCUIT
BOARD MOUNTED TO THE COVER ASSEMBLY, ARE CONNECTED BY
A RIBBON CABLE. REMOVE THE COVER CAREFULLY ONCE THE
COVER SCREWS ARE REMOVED FROM THE BACK OF THE MODULE.

Cover Installation

1. Remove the (6) Hex Socket Screws from the Heat Sink/
Base. One screw is under the Warranty/Tamper Label.

Disconnect the Ribbon Cable

1. Ribbon Cable Connector

3. Support for Cover

2. Ribbon Cable

1

1

2

3

Release Ribbon Cable

1. Ribbon Cable Connector Tabs
(Push tabs away from connector to release
cable then slide cable out of connector)

Note: Connector works same at both ends of the ribbon cable.

Reconnecting Ribbon Cable

1. Ribbon Cable Connector Release Tabs
(Slide cable into connector then push tabs
back into connector)

Note: Connector same at both ends of the ribbon cable.

1

1

1

1