4.9

OBSTRUCTION SENSOR SYSTEM -
SERVICE PROCEDURE (DVSP - OPTION)

General

The Obstruction Sensor System (OSS) Control Module is
mounted between the rails of the mast platform header sec-
tion under the platform decal billboard at the rear of the
DVSP model platform, see illustration below.

The OSS Control Module communicates with the Ground
Control Module through the platform electrical junction box
also mounted on the mast behind the platform decal bill-
board.

The OSS Control Module circuit board monitors six (6) chan-
nels each channel is wired to an individual transducer sen-
sor mounted under the DVSP model platform. The sensors
are mounted in a manner to provide a detection zone

beneath the platform and detect if an object has entered that
zone when the platform is being lowered.

NOTE: The OSS only operates normally when the Ground

Control Module - Power Selector Switch (Key) is set
to PLATFORM CONTROL MODE.
When the Power Selector Switch (Key) is set to
GROUND CONTROL MODE the OSS will detect an
obstruction but will not stop platform downward
movement or sound the horn. However, the OSS
Control Module LED will flash if a sensor detects the
presence of an object.

An OSS Sensor replacement kit is available from the JLG
Parts Department for individual sensors. The kit provides
instructions and everything necessary to connect the new
sensor to the existing soldered wire ends.

If the OSS Control Module has failed it is recommended to
replace the complete OSS system. See Section 6 of this
manual for further OSS Troubleshooting instructions.