JLG 450AJ ANSI Service Manual User Manual

Page 89

Advertising
background image

SECTION 2 - PROCEDURES

3120749

– JLG Lift –

2-71

Clutch engaged actuator retracting

Controller fault - clutch disengaged and no actuator
movement

Failure Modes

Immediate Red Light

Action:

1.

Recycle power to determine if the problem is inter-
mittent.

2.

The input voltage must be greater than 10.5 Vdc.

3.

Check wiring for any damage and correct.

4.

Disconnect engine harness and actuator connnec-
tions.

5.

If problem reoccurs return unit.

Green and either Amber light followed by a red light

or

then

Action:

1.

Inspect and clean wiring connections.

2.

Examine throttle linkage for any damage or bent
components and correct.

3.

With linkage disconnected, check each potentiome-
ter for operation.

4.

Reconnect linkage and reset each potentiometer for
correct operation.

5.

If failure continues to occur, replace unit.

Only green light on and no actuator movement

Action:

1.

Adjust trim potentiometers.

2.

If problem continues, replace unit.

Advertising
This manual is related to the following products: