5.6

BATTERY MAINTENANCE

Battery Maintenance and Safety Practices

NOTE:

These instructions are for unsealed (wet) batteries only.
if machine is equipped with sealed batteries, no maintenance
other than cleaning corroded battery terminals is required.

ENSURE THAT BATTERY ACID DOES NOT COME INTO CONTACT WITH SKIN OR
CLOTHING. WEAR PROTECTIVE CLOTHING AND EYEWEAR WHEN WORKING
WITH BATTERIES. NEUTRALIZE ANY BATTERY ACID SPILLS WITH BAKING
SODA AND WATER.
BATTERY ACID RELEASES AN EXPLOSIVE GAS WHILE CHARGING, ALLOW NO
OPEN FLAMES, SPARKS OR LIGHTED TOBACCO PRODUCTS IN THE AREA
WHILE CHARGING BATTERIES. CHARGE BATTERIES ONLY IN A WELL VENTI-
LATED AREA.
ADD ONLY DISTILLED WATER TO BATTERIES. WHEN ADDING DISTILLED
WATER TO THE BATTERIES, A NON-METALLIC CONTAINER AND/OR FUNNEL
MUST BE USED.

Check the electrolyte level of the batteries often, adding only distilled
water when required. When fully charged, battery fluid level should be
1/8" below vent tubes. (See Figure 5-2.).

DO NOT fill to bottom of vent tubes.

DO NOT allow fluid level to go below the top of the plates when

charging or operating.

Battery Quick-Disconnect -
(If Equipped)

Machines equipped with the battery quick-
disconnect allow all machine power to be eas-
ily disconnected at the batteries without
removing battery cables from the battery
posts. To disconnect power, locate the RED quick-disconnect connector
on top of the batteries inside the battery compartment and pull halves
apart.

Figure 5-2. Battery Fluid Level.

1/8 "

BATTERY

FILLER CAP

FLUID LEVEL OF FULLY

CHARGED BATTERY

VENT TUBE

PLATES

1706740A

Advertising