SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE

6-34

– JLG Lift –

3121233

4. Push in the Emergency Switch once the engine stops.

5. Disconnect the electrical connection to the LPG fuel

temperature sensor in the auxiliary fuel port of the EPR.

6. Remove the retainer clip for the LPG fuel temperature

sensor and remove the sensor from the regulator body.

NOTE: Have a small container ready to collect oil that will drain

freely from the regulator at this point.

7. Once all of the oil has been drained, reinstall the LPG

fuel temperature sensor and reconnect the electrical
connector.

8. Open the fuel tank manual valve.

9. Start the engine and verify all connections are secure.

10. Dispose of any drained oil per local regulations in a safe

and proper fashion.