SECTION 4 - MACHINE OPERATION

4-12

– JLG Lift –

3121647

4.9

INVERTER

The inverter converts 48 VDC to 110 VAC to allow operation of
power tools from the machine’s batteries.

• The inverter is operational when the emergency stop switch is

pulled out.

• The machine and inverter can be operated at the same time.

• The inverter will shut off at approximately 42 VDC and stay off

until the emergency stop switch is recycled. It will operate
again until voltage drops to 42 VDC.

• The machine will operate down to 36 VDC.

• The inverter will shut down if the high temperature light indi-

cated overheating. It will automatically turn back on when
cooled.

• The overload light indicates an output wiring short circuit or a

load that is too large for the rating of the inverter.

4.10

MACHINE FUNCTION SPEEDS

The Function Speed Control affects the speed of boom functions
Lower Lift, Telescope, and Rotate. Turn the control clockwise to
increase function speed or counterclockwise to decrease func-
tion speed. When in the counterclockwise maximum position, all
functions are placed in creep speed.

4.11

BOOM SYNCHRONIZING PROCEDURE

NOTE:

If the Lower Boom assembly does not fully lower:

1.

Remove all personnel from the platform.

2.

Pull the red knob located beside the main control valve.

3.

From Ground Control, activate the lift control switch, raise
Lower Boom 1.8 m (6 feet).

4.

After raising Lower Boom, release the red knob.

5.

Activate Lower Boom Down, fully lower boom.

6.

Repeat step 1 thru 5 if necessary.