A95218

Fig. 5—Two-Stage or Variable-Speed Furnace with

2-Speed Heat Pump

Y/Y2

W/W1

R

24 VAC HOT

FAN

FURNACE

COMPRESSOR
HI

RVS COOLING

COMPRESSOR
LO

DUAL FUEL

THERMOSTAT

TWO-SPEED

HEAT PUMP

24 VAC COM

RVS HEATING

RVS SENSING

OUTDOOR

SENSOR

CONNECTION

S2

S1

L

B

G

R

R

Y2

G

C

C

C

O/W2

Y1/W2

TWO-STAGE OR

VARIABLE SPEED

FURNACE

W2

O

SEE NOTES 1 AND 2

W/W1

Y/Y2

O

Y1

W2

Y1

W3

OUTDOOR

TEMPERATURE

SENSOR

WIRING DIAGRAM NOTES:

1. Underlined letter on dual terminal indicates its usage.

For Example: O/W2 means O, O/W2 means W2.

Outdoor Temperature Sensor must be attached in all dual
fuel installations.

Jumper wire between O/W2 and L thermostat terminals
MUST be present.

2. Y1 and O connections to 2-stage furnaces MAY NOT

EXIST, or may be only a wire rather than a screw terminal.