5 attach chute extension tray, 6 attach discharge tube, Englis h – Echo CH8670H Owners Manual v.4 User Manual

Page 11

Advertising
background image

7

8 INCH TURNTABLE CHIPPER

ENGLIS

h

ASSEMBLY

2.6 aTTach dISchaRGE TubE

Attach the discharge tube to the mounting flange

1.

on the chipper frame. Half of the mounting clamp is

already attached to the tube. Slide the tube onto the

flange and tighten the bolts to secure it.
Install the second half of the clamp to the tube and

2.

flange.
grease the zerk and tighten the nuts completely.

3.

loosen each nut one turn and attempt to rotate the

4.

tube. If it does not rotate freely, loosen each nut 1/2

turn until it rotates freely.
rotate the tube 360 degrees and lock it in place with

5.

the handle to make sure it is mounted correctly.

keep nuts as tight as possible while allowing the

discharge tube to freely turn.

NoTE

SECOND

HALF OF CLAMP

ZERK

Figure 2.4 - Discharge tube assembly

2.5 aTTach chuTE EXTENSIoN TRaY

Make sure that you position the lip on the extension

tray behind the lip on the chipper chute. This provides

a flatter surface and prevents obstructions while feed-

ing the machine.

Tilt the extension tray up, so the bottom of the tray is

1.

facing outward (Figure 2.3). Slide the extension tray lips

between the extension hinge and chipper chute lips.
Tilt the extension tray down until the tray rests on the

2.

extension hinge, and the extension tray lips contact

the back of the chipper chute lips.
Insert five 3/8" x 1" carriage bolts (included in owner's

3.

kit) through the extension tray and hinge. Secure the

bolts with washers and nylock nuts from the bottom.
attach the chute support weldment to the middle hole

4.

of the chipper chute by using the existing bolt.

EXTENSION

TRAY LIP

EXTENSION

HINGE

CHIPPER

CHUTE LIP

Figure 2.3, Attaching the extension tray