3 Mounting 

3.1 Mounting Options 

This  device  is  intended  for  integration  into  switch  panels  or  switching  cabinets.  In  order  to  allow  for  a  safe 
installation and operation (connector access), these switch panels or control desks must be accessible from the 
back. The device can be integrated into switching cabinets with a wall thickness of 2..6 mm. We recommend a 
minimum of 3 mm for correct installation with an IP65 front protection class. 

 

Warning: 

To avoid overheating in operation: The device must not be exposed to direct radiation by 
sunlight or any other light or heat source. 

If the device is integrated in a panel, casing or similar enclosures, you must ensure that no 
heat accumulation builds up. The maximum permissible environmental temperature must 
never be exceeded. 

Devices including a data drive must only perpendicularly be integrated. Any deviation 
must be agreed with ads‐tec. 

The IP65 protection class is only achieved after correct installation. 

If the device is delivered with a CD/DVD‐ROM drive, sufficient space (approx. 130mm) 
must be provided on the left‐hand side if viewing the drive from the front, in order to 
allow proper opening of the drive. 

 

 

Note: 

When selecting the enclosure for integration, the power dissipation total of the 
system including that of all integrated PCBs must be taken into account. The 
enclosure must be calculated in such a way that the maximum environmental 
temperature is not exceeded in any case. 

 