background image

LCU-ONE CAN connected to MXL QM and EVO3 QM

User Manual

Release 1.04

Channel for alarm and measure fields
box

:

Each channel of the logger can be linked to
one of the six lateral alarm leds of MXL
QM.

These channels can also be displayed on
MXL QM

display with the short name

inserted in the related cell.
Moreover it is possible to link alarm leds to
the fields displayed, enabling the checkbox
circled in the image here on the right. In this
case, when a channel displayed on a field
of MXL QM reaches a set threshold value,
the led linked to that field switches on. If
alarms are linked to measure fields, user
can only set threshold value and short
name of the channel.

Welcome text box

:

Inserting a message in the box shown here
above it is possible to show for a few
seconds a welcome message at MXL QM
start up.

Speed box

:

The logger can sample speeds coming from
sensors installed on the vehicle and speeds
coming from the vehicle ECU. It is possible
to show one of these speeds on MXL QM
display, selecting it in the drop down menu
menu of speed box. Once selected the
speed to show, it is necessary to insert
wheel circumference and pulses per wheel
revolution.

Shift light box

:

These cases correspond to the ten top leds
of MXL QM. They can be switched on at a
fixed RPM value to warn the pilot to shift
gear.

Note: always refer to MXL QM user manual for any further information concerning

the system configuration not expressly discussed in this tutorial.