7. Appendix



AirLive BU-3026/BU-3026-IVS User’s Manual

59


z

S

elect

Sensitivity

to set the detection sensitivity level. Higher sensitivity will make it

easier to detect and less objects missing, but more misjudgments.

z

Select People / Vehicles / Anything as the detected objects.

z

Select

Calibration (People or Vehicle Object Sizes)

.

The minimum and maximum

boundary of objects can be specified to improve the detection accuracy. If any false
detection caused by smaller objects, you can try to increase the minimum size.

–Min. Size of Calibration: The width and length values must be 6 pixels at least. If any

false detection caused by smaller objects, you can try to increase the minimum size.

–Max. Size of Calibration: It has to be larger than the minimum size and half the

frame size is the most.

z

In

Event Conditions,

you can specify the minimum time interval and quantity for each

alarm. And go add or edit the IVS event in the Set Event Action.

z

Enable / Disable the Counting Result Overlay.

z

Enable / Disable the Detect Line Overlay.

z

Reset Counter: Select the minimum time interval to reset the counter result.



z

Select

Rotate Mode or Transform Mode in Edit Mode:

Rotate Mode: User can rotate the zone at will.

Transform Mode: User can drag the point of the zone to any shape

z

Directionality: User can select the detected moving direction from one to another or

both the directions.

z

Statistics Record: You can configure your camera in different ways to generate the

statistics you required and statistic data can be exported in csv format file.

‐ Select Auto, camera can send yesterday report to Samba server or FTP server

automatically.

Select

and choose the Statistics Period that you want and also you can export or

reset the result.

Statistics Chart Display: Here will show the result of Trip Zone.


A.6 e-Fence

The e-Fence is an electronic fence protection system which is able to detect and send
output alert if any object is entering or leaving the boundaries you set in the camera. This
function can be used in many applications, either as a standalone protection system or
other protection systems such as airports, power plants, radio towers or even military
camps.