STEP 25

Turn off supply power before wiring ALL200RM. Turn off light switch in square box. Wire light switch

with 110V wiring. The 110V light switch leg can not be used as motor feed. Keep light and motor neutrals

separate. The light neutral is white and 10 gauge. If wired properly, a dimmer may be used. See Diagram O.

Wire Light Circuits on seperate phases (2 hots - 1 neutral).

Never wire the ALL200RM improperly. Make sure electricity is turned off when installing and/or

performing maintenance on the ALL200RM. Improper wiring and/or electricity could cause death,

personal injury, and/or property damage.

10 awg

Light Neutral

14 awg

Motor Neutral

14 awg

Motor Hot

110V Incoming

Hot For Motor

110V

Incoming

Hot for Light

Circuit 1

Diagram O

110V

Incoming

Hot for Light

Circuit 2

Black

12 awg

Light Hot

Circuit 1

Red

12 awg

Light Hot

Circuit 2