Installing the Console

Rack mount

The console fits into a standard 19” rack system

taking up 4U height. Use 4x M6 bolts with plastic protective cups.
These are usually supplied by the rack manufacturer.

Plinth mount

The console can be mounted in a custom built

plinth or other furniture. Use the cutting template detail shown
here. The dimensions allow for the console cover fixing screws.
Secure with 4x suitably long M6 bolts and nuts. Use protective
cups to protect the console surface. Shallow reliefs may be
required to allow for the face plate to cover screws.

Due to the class A topology and the lamps used the

console can run slightly warm. Do not obstruct the ventilation
slots above and below the console. Ensure that there is
adequate air flow around the unit.

To avoid radiated interference do not install the power

unit closer than 200mm (8”) to the console.

To avoid damage to the console circuits do not plug in

the DC power lead while the power unit is turned on.

Do not operate the console with its cover removed.

Do not drill any fixing holes through the console cover.

441mm (17 3/8")

172mm (6 3/4")

Template for plinth cutout

445mm (17 1/2")

175mm (6 7/8")

51mm (2")

4x M6 bolt clearance (dia 7mm)

38mm (1 1/2")

233mm (9 3/16")

4x shallow screw relief (dia 8mm)