Troubleshooting, Care and cleaning, Problem possible cause possible solution – B&K 220M User Manual

Page 13: Do not use a heavier fuse

Advertising
background image

Page 11

13005 rev 0004

Troubleshooting

PROBLEM

POSSIBLE CAUSE

POSSIBLE SOLUTION

No sound
(‘on’ LED not illuminated)

1.

Power cord not plugged in.

2.

Power off at AC source.

3.

AC power inlet fuse blown
or faulty.

4.

Control switch in the wrong
position.

1.

Reconnect power cord.

2.

Check AC switch or fuse.

3.

Check for shorts or
overloading.

4.

Place control switch in
proper position. (Page 5)

No sound on some or all
selected channels (‘on’
LED illuminated)

1.

Speaker leads loose or
faulty.

2.

Line stage to amp. cables
loose. or faulty.

3.

Source to line stage cables
loose or faulty.

4.

Line stage or source not
correctly selected.

1.

Tighten, repair, or
replace cable.

2.

Tighten, repair or replace
cable.

3.

Tighten, repair or replace
cable.

4.

Check all switch settings.

Sound lacks direction,
bass weak

1.

Speakers connected out of
phase.

1.

Check connections
making sure that cables
are connected (+) to (+)
and (-) to (-).

Loud hum or buzz on one
or more channels

1.

Poor ground connection in
interconnect cables.

1.

Check all connectors and
repair as necessary.

Low output from amplifier

1.

Balanced switch in
balanced mode when using
unbalanced inputs.

1.

Put balanced switch in
correct position.

Channel sounds distorted
and low in output

1.

Blown rail fuse.

1.

Replace blown rail fuse
inside amplifier.

** Note

:

If unit continues to blow power inlet fuses,

DO NOT USE A HEAVIER

FUSE!!,

have it serviced

.

Care and cleaning

Under normal use, the amplifier will not require any special care. Over time you may
wish to clean the exterior of the unit by wiping it with a damp cloth to remove any dirt or
dust that accumulates on it. Do not let any liquid enter the amplifier thru the vents in the
top cover. You may clean the connectors on the rear panel with isopropyl alcohol
annually.

Advertising