ML5000 Service Manual

31

Removing the Master Distribution PCB assembly

To access the Group and Auxiliary PCB assemblies it may be necessary to remove the Master

Distribution PCB.
Before beginning any service work, remove all power to the unit and disconnect any signal cables
where necessary. Ensure adequate lighting and use the correct tools.

1) Before

removing

the

Master Distribution PCB assembly, the console base must first be

removed.

2) Locate

the

Master Distribution PCB assembly positioned near the centre of the console (see

fig.7).

3)

Unplug all attaching IDC wireforms from the

Master Distribution PCB assembly.

4)

Desolder the Earth wire from the PCB then carefully remove the

Master Distribution PCB by

pulling it away from the console.

5)

To refit the

Master Distribution PCB assembly, follow the above procedure in reverse order.

Use an inspection mirror to check that each connector and IDC harness is correctly aligned
and plugged on.

Note: If a switch is fitted to the rear of the Master Distribution PCB rather

than solder links then make sure that it is set correctly. Test for correct operation.

fig.7

Master

Distribution

PCB

Earth wire

LCR Option

links or

switch

Advertising