CONSOLE FRONT

GL4000-824 inverted with the base cover removed.

E

fig. 2

Chan
24

Chan

1

REMOVE THE INPUT CONNECTOR CIRCUIT BOARD ASSEMBLY:

The INPUT CONNECTOR circuit board assembly (A) directly behind the SYS-LINK connector mountings on
the rear panel must be removed to gain access to the SYS-LINK D type connector mounting holes.
Follow the procedure below:
1

Unscrew the 16 XLR mounting screws and remove the 32 jack socket nuts on the rear connector
panel.

2

Disconnect the 8 flexible flat cables (C) from the INPUT CHANNEL circuit board assemblies.

3

Disconnectd the ribbon harness (D)

4

Carefully remove the INPUT CONNECTOR circuit board assembly (A) and place to one side.

5

Now remove the SYS-LINK blanking plate.

B

C

D

A

Only technically competent personel should attempt to fit the SYS-LINK option.
Disconnect the Power Supply Unit and cables from the console before fitting
the expander module.

s

s

s

s

s

PRELIMINARY:

To fit the SYS-LINK option it is necessary to partially remove the INPUT CHANNEL circuit board assembly
next to the GROUP 1 circuit board to enable access to the SYS-LINK circuit board mounting holes. The
INPUT CONNECTOR circuit board assembly behind the SYS-LINK D type connector mounting holes on
the rear panel will also have to be removed. It is not necessary to remove any other circuit board assemblies
as access to the SYS-LINK connections can be made with a pair of long nose pliers.

REMOVE THE KNOB CAPS:

Pull off the knob caps and unscrew the nuts from the INPUT CHANNEL next to GROUP 1 channel. The
switch caps can remain in place.
Remove the optional Meterbridge if fitted.

REMOVE THE CONSOLE BASE :

Carefully invert the console and remove the base panel by removing all screws along the edges of the base
panel. Also remove the 3 screws in the centre of the largest panel