AMMCO SM6000 PORTABLE MID-RISE LIFT User Manual

Page 4

Advertising
background image

Model SM6000

Installation, Operation, and Maintenance

File: MR6-IOM-E.doc

4

Rev:

12/12/08


Receiving

The shipment should be thoroughly inspected as
soon as it is received. The signed bill of lading is
acknowledgement by the carrier of receipt in good
condition of shipment covered by our invoice.

If any of the goods called for on this bill of lading
are shorted or damaged, do not accept them until
the carrier makes a notation on the freight bill of
the shorted or damaged goods. Do this for your
own protection.

NOTIFY

Ammco-Lifts

AT ONCE if any hidden

loss or damage is discovered after receipt

IT IS DIFFICULT TO COLLECT FOR LOSS OR
DAMAGE AFTER YOU HAVE GIVEN THE
CARRIER A CLEAR RECEIPT.

File your claim with

Ammco-Lifts

promptly.

Support your claim with copies of the bill of lading,
freight bill, and photographs, if available.


Flooring

Be certain you have the proper concrete floor to
properly handle the loaded lift. Floor should be in
generally good condition with no large cracks,
spalling or deterioration. Minimum requirements for
concrete are 4 inches minimum depth, with steel
reinforcement per local commercial practice, 3500
psi, cured for 28 days. Floor should be level within
1/4 inch over the installation area. If these
conditions cannot be met, pads can be poured to
accommodate the lift. Pad must be minimum of 8
ft x 8 ft x 1 ft minimum thickness, 3500 psi steel
reinforced mechanically attached to existing floor.

Failure by purchaser to
provide the recommended
mounting surface could
result in unsatisfactory lift
performance, property
damage, or personal injury.


Vertical Clearance

Check the height of the area where the lift is to be
installed. Clearance should be calculated based on
the full raised height of the lift plus the height of the
tallest vehicle you intend to service.


Failure by purchaser to
provide adequate

clearance

could result in unsatisfactory
lift performance, property
damage, or personal injury.

Electrical Requirements


For lift installation and operation, it is necessary to
have a dedicated 115V single-phase 60-cycle
circuit with a 20 amp circuit breaker or time delay
fuse.


Tools Required for Installation

1. Wrenches: 7/16, 1/2, 9/16, 5/8, 11/16, 15/16, 1

1/8 inch

2. Ratchet drive with the following sockets: 7/16,

1/2, 9/16, 1 1/8 inch

3. Funnel
4. Adjustable wrenches: 8 and 12 inch

WARNING

WARNING