Trip type chart – APG LOE Master Sensor user manual User Manual
Page 17
Advertising

Rev. B, 1/12
LOE Series
17
Automation Products Group, Inc.
APG...Providing tailored solutions for measurement applications
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • [email protected]
Trip
Distance
Trip
Window
ON
(closed)
OFF
(open)
Trip Type 0
(near)
Trip Type 1
(exclusive)
Trip Type 2
(hysteresis near)
Trip Type 3
(far)
Trip Type 4
(inclusive)
Trip Type 5
(hysteresis far)
ON
(closed)
ON
(closed)
ON
(closed)
ON
(closed)
ON
(closed)
ON
(closed)
ON
(closed)
ON
(closed)
OFF
(open)
OFF
(open)
OFF
(open)
OFF
(open)
OFF
(open)
OFF
(open)
OFF
(open)
OFF
(open)
Trip Type Chart
Advertising