Part Number: PT-400 - _____ - _____ - _____ - _____ - _____ - _____ - _____ - _____ - _____

A Range B C D E F G H

A. Operation / Output

□

L1▲ 4 - 20 mA output

□

L3 0 - 5 VDC output

□

L10 0 - 10 VDC output

Modbus

□

L5 RS-485 (Modbus/RTU), 4-wire

Pressure reading only

(Approvals Pending)

□

L31 RS-485 (Modbus/RTU), 4-wire

Level calculations, tank volume

(Approvals Pending)

Range - PSI

□

5

□

50

□

200

□

1000

□

5000

□

15

□

60

□

300

□

2000

□

10000

□

30

□

100

□

500

□

3000

*Other ranges available

B. Units of Measure

□

psi▲

□

bar

□

kPa

□

kgcm

2

□

fsw

C. Pressure Type

□

A Absolute

□

CG Compound Gauge

□

S▲ Sealed (100 psi or greater)

□

V VAC

□

G Gauge (less than 1000 psi)

D. Electrical Connection

(Mating connector sold separately)

□

E3 4 pin bayonet PT 1H-8-4P or equiv.

□

E4 4 pin M12 micro connector.

□

E5▲ Pigtail with cable (specify cable length below)

□

E6 4 pin per DIN 43650, short can

(mating connector included)

□

E17 6 pin bayonet (PT02E-10-6P) short can

□

E18 1/2 in NPTM with 6 in flying leads, short can

□

E19 1/2 in NPTM with cable, short can

□

E36 1/2 in NPT with 6 in flying leads, long can

□

E38 1/2 in NPTM with cable, long can

□

E39 4 pin per DIN 43650 w/Solderless screw, long can

(mating connector included)

▲

This option is standard

Automation

Products

Group,

Inc. www.apgsensors.com

tel. 888.525.7300

[email protected]

3

7/31/2013

D cont. Electrical Cable Length

□

__ Number represents cable length in ft included

on E5, E19 & E38 options.

(ex. E5-2 equals pigtail, 2 ft cable)

E. Process Connection

□

P0▲ 1/4 - 18 NPTM, 316L SS

□

P1 1/2 - 14 NPTM

17-4 SS above 500 psi, 316L SS below 500 psi

□

P5 1/4 - 18 NPTF

17-4 SS above 500 psi, 316L SS below 500 psi

□

P6 1/2 NPTF

17-4 SS above 500 psi, 316L SS below 500 psi

□

P9 H.P. SnoTrik female

(F-250C, Autoclave female) 17-4 SS above 10K

□ P30

H.P. SnoTrik male

(M-250C, Autoclave female) 17-4 SS above 10K

□

P38 1 1/2 in. tri-clover with 3/4 in. diaphragm

Available on ranges below 500 psi, 316L SS

□

P52 1 1/2 in. NPTM “flushmount

Available on ranges below 5K, 316L SS

F. Accuracy

□

N0▲ ±0.25%

□

N1 ±0.25% with NIST certification

□

N2 ±0.1% with NIST certification (select ranges)

□

N12 ±0.5% (available from 10K - 40K)

□

N13 ±0.5% with NIST certification

(available from 10K - 40K)

G. Materials

□

M1▲ 316L SS (1 to 40,000 psi)

□

M2 17-4 SS (available on ranges > 200 psi)

H. Temperature

□

S0▲ Standard: 0º - 130ºF (-17º - 54ºC)

□

S1 Extended: -40º - 180ºF (-40º - 82ºC)

M0 316 SS

□

S1 Extended: -40º - 180ºF (-17º - 54ºC)

M2 17-4PH SS

□

S4 Extended: 0º - 185ºF (-40º - 82ºC)