• Wiring
Wiring should be in accordance with all local codes. We recommend the use
of solderless lugs for connection.
Switch rating (resistive)
AC
DC
Maximum capacity
50 VA
50 W
Maximum current
0.5 A
0.5 A
Maximum voltage
300 V
300 V
1. TLS-8
VCTF 2 x 0.75 mm
2
2. TLS-8B
VCTF 2 x 0.75 mm
2
3. TLS-8AK
SPVCTF 2 x 0.75 mm
2
CAUTION! DO NOT EXCEED THE CONTACT RATINGS!
1.
Overvoltage
Reed switches are not designed for the direct starting of inductive loads such
as motors, contractors, solenoid valves, etc.
2.
Overcurrent
Momentary surge current may be produced by switching lamps or stray
capacity from long cable length.