• Adjustment
1. DETECT Switch
For shifting the magnetizing state of the
output relay. The magnetizing state of the
output relay is as follows:
At Non-Detection
At Detection
Detect On
OFF
ON
Non Detect
ON
OFF
2. OFFSET Adjusting Trimmer
An offset adjusting trimmer for noise
component
left ... larger right ... smaller
3. GAIN Adjustment Trimmer
An adjusting trimmer for amplifying only
input signals
left ... smaller right ... larger
4. ON DELAY Adjusting Trimmer
A time adjusting trimmer for ON DELAY
Max. setting time is approx. 7 seconds
5. OFF DELAY Adjusting Trimmer
A time adjusting trimmer for OFF
DELAY. Max. setting time is approx. 7
seconds
6. LED Display
The red LED (4 pieces) indicate the
intensity of input signals. When the LED
illuminate, the relay will be switched on.
1
6
5
4
3
2
NON
DETECT
ZERO
RY ON
DELAY
DELAY
GAIN
OFFSET
OFF
ON
DETECT