Configuration by telnet, Configuration by serialmanager utility, Configuration by web browser – Atop Technology SE5002 Installation Guide User Manual

Page 4: Pin assignments, Full duplex, 4 pin assignments

Advertising
background image

Quick Start Guide Version 1.3
ABLELink

®

Ethernet Serial Server

SE5002

Copyright © 2006 Atop Technologies, Inc.

All rights reserved. Designed in Taiwan.

3

A Configuration

by

Telnet

1.

Telnet to SE5002 using DOS command “Telnet IP_address”. Example: telnet 10.0.50.100

2.

SE5002’s network, link mode and COM ports settings can be configured in the telnet window

B Configuration

by

SerialManager Utility

Use SerialManager on Product CD to configure the SE5002.First click” Configuration” then assign a

static IP.

C.

Configuration by Web Browser

1.

Make sure the PC is on the same network as SE5002

2.

Open a web browser, then Enter in the IP address as the SE5002. The default user name is

admin and default password is null (leave it blank).

3. The SE5002’s network, link mode and COM ports settings can be configured on different web

pages.

4. Click

Save Configuration” to save settings.

5. Click

Restart” button to initiate the change.

4 Pin

Assignments

The pin assignments of DB9 connector on SE5002 is shown in the following table:

Pin#

RS-232

Full Duplex

for SE5002 Model

RS-485

2 wire, Half Duplex

for SE5002 Model

RS-485/RS-422

4 wire, Full Duplex

for SE5002 Model

1

DCD

N/A

N/A

2

RXD

N/A

(reserved)

TXD+

3

TXD

DATA+

RXD+

4

DTR

N/A

N/A

5

SG (Signal Ground)

SG (Signal Ground)

SG (Signal Ground)

6

DSR

N/A

N/A

7

RTS

DATA-

RXD-

8

CTS

N/A(reserved)

TXD-

9

N/A

N/A

N/A

The pin assignments of Terminal Block connector on SE5002-S55is is shown in the following table:

Pin#

RS-485/RS-422

4 wire, Half Duplex

For SE5002-S55is

RS-485

2 wire, Full Duplex

For SE5002-S55is

1

T+ NC

2

T- NC

3

R+ Data+

4

R- Data-

5

SG (Signal Ground)

SG (Signal Ground)

Customer Services and Supports

1. Contact your local dealers or Atop Technical Support Center at the following numbers.

y +886-3-550-8137 (Atop Taiwan)
y +86-21-6495-6232 (Atop China)

2. Report the errors via Atop’s Web site or E-mail account

www.atop.com.tw

,

[email protected]

www.atop.com.cn

,

[email protected]

Advertising