TROUBLESHOOTING (cont.)

PROBLEM

Brew cycle will not start (cont.)

Water is not hot

PROBABLE CAUSE

REMEDY

10737 120800

Refer to Service - ON/OFF Switch
for testing. See page 16

Refer to Service - Start Switch for
testing procedures. See page 20

Refer to Service - Timer for testing
procedures. See page 24 or 25

Refer to Service - Solenoid Valve
for testing procedures. See page
19

(A) Direction of fl ow arrow must
be pointing towards brewer.

(B) Remove the strainer/fl ow con-
trol and check for obstructions.
Clear or replace.

Refer to Service - Tank Heater
Switch for testing procedures.
See page 22

Refer to Service - Limit Thermo-
stat for testing procedures. See
page 16

Refer to Service - Control Ther-
mostat for testing procedures.
See page 15

Refer to Service - Tank Heater for
testing procedures. See page 21

Refer to Service - Recovery
Booster for testing procedures.
See page 18

3. ON/OFF Switch

4. Start Switch

5. Timer

6. Solenoid Valve

7. Water strainer/flow control
(.222 GPM)

1. Tank Heater Switch

2. Limit Thermostat
CAUTION - Do not eliminate or
bypass limit thermostat. Use only
BOM part #29329.1000

3. Control Thermostat

4. Tank Heater

5. Recovery Booster (CWT 2/2,
CWTF 2/2 & 0/6 Only)