INSTALLATION INSTRUCTIONS
WIRING INFORMATION FOR SOLENOID
• The solenoid requires 24-volt DC power. Applications of other power sources will
result in sever damage to the interlock.
• The DC power is obtained through the use of a rectifier that is supplied in the
electrical control enclosure.
• The proper solenoid connections for 24-volt DC operation are to connect the
RED and WHITE leads from the solenoid to the correct terminals in the electrical
control enclosure.
• The BLACK and BLUE leads of the solenoid must be wired together.
• See
Figure 10 for wiring diagram.
DANGER
!
Qualified personnel only!! Only qualified service personnel
should perform procedures labeled as “dangerous”!
Figure 10 – Interlock Wiring