Installation instructions, Danger – Autoquip GATES SWING User Manual

Page 22

Advertising
background image

INSTALLATION INSTRUCTIONS

WIRING INFORMATION FOR SOLENOID

• The solenoid requires 24-volt DC power. Applications of other power sources will

result in sever damage to the interlock.

• The DC power is obtained through the use of a rectifier that is supplied in the

electrical control enclosure.

• The proper solenoid connections for 24-volt DC operation are to connect the

RED and WHITE leads from the solenoid to the correct terminals in the electrical
control enclosure.

• The BLACK and BLUE leads of the solenoid must be wired together.

• See

Figure 10 for wiring diagram.

DANGER

!


Qualified personnel only!! Only qualified service personnel
should perform procedures labeled as “dangerous”!


Figure 10 – Interlock Wiring


22

Advertising