Danger ^ warning – Autoquip TITAN SCISSOR LIFT TABLE User Manual

Page 22

Advertising
background image

22

Figure 6.1


If for any reason you are unable to lower the lift completely onto the
maintenance devices, stop immediately and consult the factory. Failure to
properly use the factory approved maintenance devices could result in
severe injury or death.


5. Once the maintenance devices are properly and securely engaged, continue to press the down

button, valve or switch for an additional 5-10 seconds to relieve all pressure in the hydraulic system
(it could take longer in a pneumatic system).


Failure to relieve operating system pressure could result in the sudden
and unexpected release of high-pressure fluids (or air) during
maintenance and/or repair of the lift, resulting in severe injury or death.


6. Follow OSHA electrical lock-out/tag-out procedures. Disconnect and tag all electrical and/or other

power sources to prevent an unplanned or unexpected actuation of the lift.

7. Once inspection or work is complete, reverse the performance of the steps above to raise the lift

off the maintenance devices and place the devices back into their designated storage positions.



^ DANGER

^ WARNING

Advertising