Oil Viscosity Recommendations

Environment

(Ambient Temperatures)

Recommended Oil

Indoor location, variable
temperatures (30 - 100° F)

10W30 or 10W40

Multiviscosity motor oil

Indoor location, consistent
Temperatures (70° F)

SAE-20W motor oil

Outdoor location, (-10 - 100° F)

SAE 5W30

Multiviscosity motor oil

Cold-storage warehouse
(10 - 40° F)

5W30 Multiviscosity motor oil

Freezer (-40° F to 0° F)

Consult Factory

OIL CAPACITY:

Reservoir capacity for the “contractor” (polyethylene) tank is approximately five gallons.

The oil level in the reservoir should be 1” to 1 _” below the top of the reservoir with the
lift in the fully lowered position.

PIPE THREAD SEALANT

Loctite PST #567 pipe thread sealant or equivalent is recommended. Do not use
Teflon tape.
Tape fragments can cause malfunctioning of the hydraulic system.