Lift raises slowly.

•

The structural members of the lift may be binding.

•

The tubing or hose is obstructed or broken. Where

pipe is used, check for obstruction in the line.

•

The hydraulic line or hose may be leaking.

•

The oil viscosity is not suited for the environmental

conditions. Refer to “Routine Maintenance” section
for oil recommendations.

•

Check the oil level in the reservoir.

•

The motor voltage/wiring may be incorrect.

•

The suction filter may be clogged. Remove and

clean the filter. Drain and replace the oil.

•

The breather holes in the reservoir fill cap may be

clogged. Remove and clean.

•

The power unit pump may be defective.

Lift lowers slowly.

•

The structural members of the lift are binding.

•

The tubing or hose is obstructed or broken. Where

pipe is used, check for obstruction in the line.

•

The oil viscosity is not suited for the environmental

conditions. Refer to “Routine Maintenance” section
for oil recommendations.

•

The return filter may be clogged due to dirt or

damage.

PROBLEM

POSSIBLE CAUSE AND SOLUTION

TROUBLESHOOTING ANALYSIS